Personal Care
With the increasing concerns on recent years outbreaks of COVID-19 , it is more important than ever to understand how to have the appropriate and safe protection from infection.
CMA Testing provides the raw materials and face mask testing and consultancy services for US, Europe and Asian markets. Manufacturers and importer can get our comprehensive support from raw materials quality control to final inspection of personal care products.
We offer :

Materials - Melt Blown Nonwoven Fabric / Melt-blown Fabrics :
ASTM F2100/ EN 14683
- Differential Pressure (Delta P) (mm H₂O/cm²)
- Bacterial Filtration Efficiency (%)
- Particulars Filtration Efficiency (PFE)
- Fiber Glass Detection
EN 12586
- Formaldehyde Test
Others
- Tensile Strength and elongation Test
- Azo Dye Test
- Residual ethylene oxide Test
- Microbiological Test
Masks - Surgical Masks :
ASTM F2100
- Bacterial Filtration Efficiency (%)
- Differential Pressure (mm H₂O/cm²)
- Sub-micron Particulate Filtration Efficiency (%)
- Resistance to Penetration by Synthetic Blood (mmHg)
EN 14683
- Bacterial Filtration Efficiency (%)
- Differential Pressure (Delta P) (Pa/cm²)
- Splash Resistance (kPa)
- Microbial Cleanliness (CFU/ g)
AS 4381
- Bacterial Filtration Efficiency BFE (%)
- Differential Pressure (Delta P) (mm H₂O/cm²)
- Synthetic Blood Penetration (mmHg)
Masks - Fabric Masks/ DIY Barrier Mask :
This is the guideline developed by The French standards association for non-medical woven masks.
AFNOR SPEC S76
- Visual Inspection and Dimensions
- Packaging and Materials
- Marking and Labeling
- Cleaning and Drying
- Breathing Resistance (Breathability), and
- Penetration Resistance (Particulate Filtration)
Respirators :
Requirements of Respirators are more complicated than surgical masks. There are common parameters among the standards, filtering efficiency , differential pressure, etc. Other tests from different countries will have different parameters to measure the performance. Please find the following countries standards and the detailed information of performance test from our White Paper : Standards of Respirators
Countries | Standard |
USA | 42 CFR 84 |
EU | EN 149 |
China | GB 2626 |
Australia/ New Zealand | AN/NZ 1716 |
Korea | KMOEL – 2017 - 64 |
Japan | JMHLW Notification 214 |
Particle Filtration Efficiency (PFE) Tester
Contact:
South China:
Tel :(86) 0755 8835 0808
Fax : (86) 0755 8835 1430
oll Free:800 999 8168(within China only)
Email:info.sc@cmatesting.com.cn
East China:
Tel:(86) 021 6433 0500
Fax:(86) 021 6431 6663
Email:info.sh@cmatesting.com.cn
Contact Us
(86)755 8835 0808 / 21 6433 0500 | |
(86)755 8835 1430 / 21 6431 6663 | |
info.sc@cmatesting.com.cn / info.sh@cmatesting.com.cn | |
Subscribe to our newsletter |
To understand more about us, please download our service brochure.